Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the formula to find out how many amps generater
takes running on full load.

Answer Posted / mallikarjun

I=KW/SQRT3*V*0.08

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?

2412


What is power relay?

1299


PLEASE TELL ME ABOUT QUESTION PAPER OF UPCL ENTERENCE EXAM.

8055


What is depreciation factor?

2318


Capacitor is load free component but why ampere meter shows current when capacitor bank breaker close?

1240


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2166


design of IGBT firing circuit for 11KV

2711


What is contract demand in solar system?

1753


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


how to calculate mf when meter and cTPT detail are given

1895


what are the parameters plays a major role in Potential transformer Burden calculation??

2279


How to design the earth grid for lightning protection in an industry

4791


calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.

3621


What is the function of interposing current transformer?

1106


1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve

2053