What should be the stanchan Height for installation of
Smoke detector & toxic gas detector in field,according to
qatar standard
Answer Posted / வி
Height Factor should not be considered for Installing detectors both Smoke Detectors and Toxic Gas Detectors.
And there is no standards for countries such as qatar.america.
The concept is where the emission exists of gas leak or smoke,
while installation we have to be aware of Future preventive Maintenace. The Installation should be such it has to sense the existience of gas and it should be suitable place for calibration,preventive maintenance,and for corrective maintenance.
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
please send me the inteview questions in IOCL
䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ
Make Heater Process Logic.
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
How to find out the current of two motors having same power consumption but different RPM?
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
How do you identify an orifice in the pipeline?
1- Explain about HPM 2- What is the FSC and explain the configuration of FSC 3- explain the complete loop of vibration, how it works (field to control room) 4- What is the use of proxymitter? 5- During job your partner effected with H2S then what you have to do. 6- what type of gland packing uses when valve glind is leaking.
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,