What should be the stanchan Height for installation of
Smoke detector & toxic gas detector in field,according to
qatar standard
Answer Posted / வி
Height Factor should not be considered for Installing detectors both Smoke Detectors and Toxic Gas Detectors.
And there is no standards for countries such as qatar.america.
The concept is where the emission exists of gas leak or smoke,
while installation we have to be aware of Future preventive Maintenace. The Installation should be such it has to sense the existience of gas and it should be suitable place for calibration,preventive maintenance,and for corrective maintenance.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
Difference between ultra sonic flow meter
how do we commission inergen system?
hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v
I am teja. I am studying Msc(tech) Electronics and Instrumentation (3years course) in Andhra university. But my course is not recognised by UGC and AICTE. Please tell me the job opportunities after this course. And i fineshed PLC course in IGIAT ,Vizag.Also complted my short term coure in SCADA, Seimans WinCC in ATI,Hyd.After Msc can i join Mtech for good job? or phd. How i can get good job in INdustrial Automation Side. Please give replay.Because this is my life matter.
how works encoder in plc
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
what is the process to make control schematic ?
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
Question on maha cement
What is the GK Value in Flowmeter?