What happens if you give supply to the rotor of three phase
induction motor?
Answer Posted / ranjit kumar mallick
It is quite difficult to provide three phase supply to a
rotating object like rotor.As you know in case of squirel
cage motor the rotor is shorted through end rings so
breaker will trip once you give supply to shorted motor.In
case you open circuit the rotor winding and then you give
three phase supply but you have check the phase squence of
stator and rotor to make the stator magnetic field follow
the rotor magnetic field.Initially the motor will start
with very high torque but afterwards it will become very
messy to calculate the load current, voltage etc due to the
effects of faraday and lenz law and the behavior becomes
unpredictable. I will sugest not to make such
experiment.Any way the three phase slip ring is mostly
unavailable to make this experiment.
| Is This Answer Correct ? | 6 Yes | 9 No |
Post New Answer View All Answers
How to calculate multiplication factor in kva example 500kva ans pls ?
what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?
what is x'mer ,isolation x'mer & yltra-isolation x'mer?????
Which is the oldest hydropower plant in india?
our industries ht line so power fluctation(once drop of power please rectify causes
What the main causes of transient interruptions on Over-Head Distribution Lines?
'documenˁ
BSNL TTA EXAM QUESTION
what is the preventive maintence for ht panels and busbars and vcb abd acb's.
how can we say that stator magnetic field rotates with synchronous speed?can we derive?
Any Electrical Engineering jobs?Please refer for interviews. Thank you
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
why normally Generator rating are between 11Kv to 22Kv?
TRAFO 1. WHY BREATHER IS USED. 2. WHY OIL GOES DOWN IN CONSERVATOR TANK. 3. WHY WE ARE TAKING OIL SAMPLE TAKING FROM BOTTOM OF TRANSFORMER. 4. HOW TO CHECK IR VALUE OF TRANSFORMER. 5. WHY OLTC HAVING BUCHHOLZ TRIP ONLY; WHY NO ALARM. 6. OFF LOAD TAP CHANGER OPERATION PROCEDURE. 7. TR. SHUTDOWN / ISOLATION PROCEDURE. 8. WHEN THREE TRS. IN PARALLEL, ONE TR. IS NOT SHARING THE LOAD – WHAT IS REASON AND WHAT YOU WILL DO. 9. WHY TR. HAS OLTC IN HV SIDE. 10. WHAT IS % IMPEDANCE. 11. WHY TR. RATING IN MVA. 12. WHAT IS VECTOR GROUP IN TR. 13. CONDITION FOR PARALLEL OPERATION OF TRS. 14. WHAT IS TERTIARY WINDING. WHERE IT WILL BE. 15. IF TR. TRIP ON BUCHHOLZ OR TAP CHANGER RELAY, WHAT YOU WILL DO. 16. DIFFERENCE BETWEEN OIL TEMP. AND WINDING TEMP. PROTECTION 17. HOW WINDING TEMP. IS MEASURED IN CAST RESIN TR. 18. DIFFERENT TYPES OF FAULTS IN TR. Trafo - Page-1 of 2 19. WHAT HAPPENS WHEN TR. CHARGED FROM LV. 20. WHAT WILL YOU DO IF MEGGER READING SHOWS ZERO BETWEEN LV WINDING AND EARTH. 21. CAN WE INTERCHANGE BUCHHOLZ RELAY OF MAIN TANK AND OLTC TANK. 22. IF THE LINE BETWEEN BREATHER AND CONSERVATOR TANK 23. LOCKED, WHAT WILL HAPPEN DURING LOAD CYCLE. 24. WHAT IS THE FUNCTION OF OIL SEAL IN BREATHER. 25. WHAT ARE LOCATIONS FOR BUCHHOLZ RELAY FIXED IN POWER TR. 26. WHAT ARE CHECKS IN POWER TR. DURING MAINTENANCE. 27. WHAT IS IMPORTANT WHEN WE CHECK OLTC OPERATION DURING MAINTENANCE. Trafo - Page 2 of 2
What do you mean by reach and reach the point of the relay?