what is meant by unity power factor?unity means one why dont
call 2,3,4......?
Answer Posted / nimmi
It is often desirable to adjust the power factor of a
system to near 1.0. This power factor correction (PFC) is
achieved by switching in or out banks of inductors or
capacitors.that is the reason the power factor is always
maintained at 1.0 and called as unity power factor.
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain
Explain the process of commutation in a dc machine.
Yazaki india pvt ltd interview questions qurey related
How to configure the drives in PLC, through Profibus commnication. And to how to address it?
HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER
what is the IEC standard for Power Cable installation in onshore (like in direct buried ground or above groung)
what does a string of resistors in a series will do?
what is the use of permanent magnet generator in exciter
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
What is the permissible maximum flux density in transformer core?
What is meant by a stray loss of a induction motor??? What is the equation to find it
Can I use star delta connected induction motor for dual supply voltage?
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
Define filter?