Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is meant by unity power factor?unity means one why dont
call 2,3,4......?

Answer Posted / nimmi

It is often desirable to adjust the power factor of a
system to near 1.0. This power factor correction (PFC) is
achieved by switching in or out banks of inductors or
capacitors.that is the reason the power factor is always
maintained at 1.0 and called as unity power factor.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.

2409


whati s the sludge current in ups

2237


What is the Current equation in series RLC circuits.

1041


what is strip power factor?

2154


How can we measure the residual voltage in dc machines?

1858


Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core

3137


what irequirment need to be followed when working on live equipment

1776


How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?

3180


The Q-facr o of a coil given as wL/R. what will be shape of Q versus frequency graph.

2015


What does the kvar means?

1201


What is the tension required for the 25000 CFM AHU belt

2478


Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC

2111


What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?

1926


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

2091


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1942