Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

they conducted technica for 1 hour..i also managed..they
selected 5 boys and only one girl,myself got wait
listed.whether they would call or not

Answer Posted / venu

sure u will be called

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why power genaration in India is at 50HZ while America its 60HZ

2283


how to fit 3 HP crompton gear motor with conveyor with the use of staring delta starter or ordinary starter?

2004


What is the meaning of dedicated earthing?

2156


earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

1962


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2146


How to discuss the phase shift of transformer considering open delta?

1463


What are the different circuits in thermal power plant?

1177


What is meant by analogous system?

1286


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1690


how to select proper cable for ct wiring so that drop within the limit.

1967


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1979


Define cuttoff frequency?

1061


what is there inside an inverter and how it works?

1831


explain types of electric welding and its applications

1790


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1974