Answer Posted / kunal
The breakdown voltage of an Insulator is the minimum
voltage that causes a portion of an insulator to become
electrically conductive
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what parameters are should nessary for control technic dc drive(in rolling mills)?
Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?
Whats the difference btwn a latch, port,data bus buffer? Do they all not hold data in d flip flops??
How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?
l&t switch FN 63 handle position can we change
CAN CU XLPE/PVC CABLE BE USED INPLACE OF LOW NOISE SCREENED CABLE? KINDLY GIVE REASONS
What is the Minimum winding resistance of motors ( small & big)? referance range
I am going to appear for the RRB Chennai Section Engineer online exam. Please send me the question papers from 2001 to date to my mail id:upendrakrishna20@gmail.com,plz send me ,or send any other rrb papers plzzzzzzzzzzzzzzzzzz
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
what are the main faults that occur in stabilizers? How they corrected and resolved ? Types of stabilizers ?
Show the schematic arrangement of diesel power station layout and give its principle of operation.
what is the difference between directional & non directional earth fault with example please explain.