Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if only one generator is running in droop mode parrallel
with grid and suddenly grid breaker off what will happen?
It will trip o/u freq or stay as it is? (urgent)

Answer Posted / hamid

If this happen then turbine rpm and exactly frequency goes
up and depending on reaction of your control system to speed
variation , speed may be control or just lock out relay of
generator operate and turbine should not trip .

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1933


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1891


Do closed loop systems require manual input?

1097


what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.

2148


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

2044


What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com

1828


Why did lightening arrestor solid copper rod head is sharp on mobile tower top?

1951


bsnl tta exam question

1830


Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV

2126


Please brief working principle & construction of permanent magnet AC Servo motor

2166


The electromagnetic torque developed is proportional to what in a D.C series motor?

1112


11000volt DG set carnt kaise banvay

1625


How to calculate wire length,size & current? ( related to control panel)

2129


how to find the multiplication factor for digital energy meter and analog energy meter

2155