Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the voltage values for LT,HT,EHT and other
voltages??

Answer Posted / sr

Low voltage upto 1.1kV
Medium Voltage from 6.6kV to 33kV
High Voltage from 66kV upto 132/110 kV (in Karnataka)
Extra High Voltage from 220 kV & above.

Is This Answer Correct ?    24 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2818


In a synchronous motor. if start is running at high speed.  What will be the starting torque : Higher Lower Zero

1723


What is the difference between amorphous core transformer and CRGO core transformer?.

3743


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2349


What is domestic transformer? Draw the connection of domestic transformer.

2323


what is transformor oil gread

2541


Single phase and threephase power calculation

2144


How can we findout the maximum efficiancy of Transformer? At which load?

2088


What is the Load Capacity of Panther conductor (0.2) and dog conductor (0.2) 

2835


iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.

2256


delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?

2004


WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?

1760


What is the approximate value of stacking factor?

1162


is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?

1862


i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.

2217