How can w select the cable size for different rating load
& also waht r factors affecting the during selection of
cable?
Answer Posted / eng.yousef
cable size depends on:
1)total connected load via cable.
2)lenght between the source and the load.
3)temprture
4)isulator type
5)load type
6)wiring place& type
| Is This Answer Correct ? | 16 Yes | 13 No |
Post New Answer View All Answers
what is the star delta connetion and how can do it a three phase motor with control witing with picture
For electrical designers what are the standard should know? i want learn about this standards. how to get information/reference. anybody help in this regards please.
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
what is the disadvantages of common earthing for AC and DC equipment? (i am talking about inverter control room and inverter duty transformer earthing is common...?)
i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls
which type of stability limit is higher,steady state or transient? why?
What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.
What is capacitance?
Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA
why we use the 100% and 95% stator earth fault protection for the synchronus generator ?
can u give me a brief idea about power line carrier communication ??
5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch
what irequirment need to be followed when working on live equipment
WHY IN AC DRIVES,INPUT PHASE CURRENT SHOW UNBALANCE?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?