Distinguish between neutral earthing and equipment earthing?
Answer Posted / m. p.renu.
There is an advantage of body earthing and neutral earthing
interconnected, since any single phase connected load if
interchanged, the fuse or the circuit trips indicating the
phase wire is wrongly connected.In any case the earthing
system works when there is a normalleakage and as we have
interconnected the two earthing system the total earth
resistance becomes low & this is an added advantage.
If not so kindly explain.
Is This Answer Correct ? | 4 Yes | 7 No |
Post New Answer View All Answers
How two nos. 130 kw D.C motor get synchronise using D.C drive.
Minimum IR value of 1.1 kv grade 3.5c (300, 240,185,150,120,95,70,50,35,25) sqmm Aluminium XLPE cable and 4c (16, 10,6 & 4) sqmm cu arm cable between RY,YB,BR,RN,YN,BN,RE,YE,BE & NE.
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased
what is the minimum winding resistance of 30hp compressor, to run or to switch on
what is the sludge current
define the non synchoronism of synchoronous machine in general g or m??
what are problems caused by the pdu in rack server
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
What are the advantages & disadvantages of a group electrive drive?
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
differnce between single acting and double acting solenoid valves
Which is the largest hydropower station in the world?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
How many types of instrument cables are there?
how we can do the insulation on secondary of ct explain and so that tan delta will within limit