Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why transformer is not rotating?

Answer Posted / subba lakshmi

transformer is not rotating bcoz for rotating rotating
magnetic field is required which is produced only when the
current is passed through the windings which are displaced
physically by 120degrees and phase difference of 120
degrees where as in transformer there is no phsical
displacement of 120degrees hence transformer cannot rotate.

Is This Answer Correct ?    84 Yes 21 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?

2300


What is Harmonics how it is produced and what is the method to control the same

2332


300m long and 30kw inductive loade 3phase supply how many size cable required

1485


what is strip power factor?

2224


What is the minimum underground tank size capacity considered for firefighting purpose?

2005


from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?

2090


WHY THE DIMENSION OF TWO SAME RATED MACHINE IS DIFFERENT ?

2278


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1554


What is Bolted fault?

2269


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1798


Explain what are inter-poles and why they are required in a dc machine.

1140


how is capacitor bank look like

2451


For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1878


how to conduct dc resistance test for rotor of an alternator and how to measure the rotor dc resistance value theoritically?

3346