Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to find Cable size?
Caterpillar generator produce (Two generators) 127*2=254 amp
at 11 kv .
What would be the cable size (XLPE) to supply 256 amp at 11
kv? Air or surrounding Temperature is 32 degree C. Cable
will go under ground at 2.5 feet depth. Group Rating Factors
is 3 cables. Clearance between cables is 7 cm. Soil
Temperature (Ambient) 28o C Soil Thermal Resistivity is 1.2
K.m/W


I would like to use 3 separate single core instead of using
3 core cable.

Some says I should use three separate single core 120RM cables.
Some says 70RM .some says 95.
I m totally confused.
Is there ant specific rule to determine cable size?
What would be the LT cable size to flow 500 Amp current?
Ifte
My e mail address is ifte13@yahoo.com
Anyone please send me the answer to my e mail address,
i will be very glad.

Answer Posted / muhammad qasim

Dear, All those specification you described in your question
are cared while manufacturer design their product. Designing
contains many complex parameters to be cared while deciding
about the metallurgy, insulation. All good manufacturer care
worst operating conditions when they design their products.
When we go for their usage in industrial sector, main things
we need to assure are that:

1- Current Raging
2- Voltage Drop should not exceed the permissible level
3- Cable should have withstanding capability for transient
short circuit and thermal capability.

Normally, copper have current density of 1000 A/Sq inch
which becomes 1.8 A/Sq mm. and all cable and bus bars should
be designed 150% of operating rating for safety purpose.

Secondly, Conductor area is not affected with voltage level,
50 A at HT or LT shall require same conductor area but
insulation level shall be affected. For HT you need XLP and
for LT you need PVC-PVC cables.

Further if you get better answer please copy the same to
muazmi02@yahoo.com

Regards

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why connecting surge unit in contactor coil

1868


WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

4056


In Power cable specification what is U0/U and Um.

3790


How to justify this statement ??? "Capacitors in series provide less capacitance but higher voltage breakdown rating for the combination"

1867


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

2360


i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls

2142


which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

2495


Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.

3798


What is advantages of VSCF wind electrical system?

2325


Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more

2024


How many devices can be connected in one zone of FACP

2310


Please define ohm’s law for a.c (alternating current)?

1070


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2140


What happen if 200 KVAR capacitor connected to power continuesly?

2118


What is the type of earth fault protection used in battery? explain.

2297