what is the working difference b/w softstarter and
Variable frequency drive ?
Answer Posted / kk_london
in soft starter you cannot control the speed of motor where
as in vfd drives speed can be varied by giving digital
inputs to the drive via plc. But both can control the
starting torque of the load.
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
how to calculate the power factor when instantaneous voltage and current has harmonics in it ?
What is power relay?
How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence
how the phase convertor changes the no. of phases
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?
what is metering cum synchronizing panel and how it is used?
how to check ac servo motor
What is transient response?
What is the approximate value of stacking factor?
what is cascade speed control device?and how this device control the speed of motors?
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
we have an energy meter in a capacitor bank panel, So should we consider it's readings as energy consumption on daily basis. (when capacitor bank doesn't have any energy losses)