what are the three main programming languages in plc
Answer Posted / praveen kumar
Ladder Logic, Sequencial function chart, Gate logic
| Is This Answer Correct ? | 5 Yes | 8 No |
Post New Answer View All Answers
What are the different types of thermistors used in industries? How to the operation of typical thermistor?
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
2. What is ultrasonic flowmeter?
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,
Reason for capillary type dp level transmitter fluctuation
Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
What is the difference between uv and ir scanners? and what is the workig principle of both
can any send me a forbes marshall dtron 316 manual
What is the purpose of the analyzer in petrochemical plant?
How servomotor controls throttle valve of TURBINE?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Calibration of controller (pneumatic)
what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other