Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in our sub station why we step down firstly 33kv\11kv then
11kv to 430v. can we direct step down 33v to 430.v.

Answer Posted / devesh mishra

yes we can directly step down from 33/.433kv.
the lv side remains constant for 11 or 33kv & hv side
depends on load i.e,

for load upto 4 mva 11kv ht line is required,whereas
for load above 4 mva 33kv ht line is required.

Is This Answer Correct ?    40 Yes 25 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

1863


Is there any standard guidelines/Criteria to design NGR/NGT.?

2785


what are the specifications we must look at to select a relay for any capacity motor?

1990


Has someone here done a sizing for a generator (3 phase), its for a pumping station. If you have an example for standby/duty and both running (I) star delta (ii) Soft Starter.

2087


how to calculate the distance relay faulty zone?pls explain?

2001


Why do we need interlocking in a HT metering or Ring main unit switchgear?

1950


Why power factor should not be in leading (capacitive) mode of any load.

6846


What is the formula for calculating impedance of transformers connected parallel at fault level 50KA?

2015


What is the capacitance values of 132,220,400 & 765 kV current transformer

1859


What does Bode plot tell you?

1312


what is the significance of cabability curve of alternator

2166


We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.

1800


How calculated single phase induction motor req. Capacitor?

1521


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2262


given data are load current & power factor cable core size? plz any one update the calculation formula

1842