if only one generator is running in droop mode parrallel
with grid and suddenly grid breaker off what will happen?
It will trip o/u freq or stay as it is? (urgent)
Answer Posted / atul pradhan
Paralelling with grid mean your DG is running on stand by
mode or droop mode, your systems load is on grid. when grid
trips all load shifted on DG WITHOUT INTERRUPTION when grid
power comes check synchro. relay gives command again to DG
& it will again run on droop mode.
| Is This Answer Correct ? | 1 Yes | 6 No |
Post New Answer View All Answers
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
What are the types of excitation system?
Where voltage are high and current to be interrupted is low the breaker preferred is:
What is meant by stator?
How to measure the earth resistance value in a concrete pavement(flood light area)?
We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
What is the effect of pi controller on the system performance?
What aturn on methods of scr?
How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com
if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value
what is the principle of operation of tungstun bulb ??
Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT?