How to convert farad to kvar.
both are the unit of capacitor.

Answer Posted / jack

a var is a unit of reactive power

a farad is a unit of electric capacitance

see convert-units.net

Is This Answer Correct ?    60 Yes 23 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.

1254


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

1522


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1364


Why Stabilising Resistor used in REF circuit ?

2731


What is difference between safe PLC and normal PLC

1000






WHAT IS DEAD END IN PROTECTION?

2013


How can maintain our H.T. motors used in cement plant. please send me procedure.

4675


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1671


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1586


we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.

1580


Draw the circuit of clapp oscillator?

677


what is the importance of Partial Dischage test for Electrical Equipments

1469


why and where we use early make & late break contacts in protection?

7637


why do we lay up the core of a cable?

1612


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1217