Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why are using bus ducts ? why not using cables

Answer Posted / anand kumar shukla

as we know very well .we are use the busbar in busduct
because the current bearing rating of busbar is too much
high in compare to the cable.
we use the 150 x12 mm
150 x10 etc.
so the busbar mechanical strenth is too much strong than
cable. and busduct life is too long in compare to cable.

Is This Answer Correct ?    65 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC

2082


What is called limb of a transformer?

1013


any one can explain the stages of a knee point which is taken during ct magnetising curve.

1744


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9076


Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.

2356


At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?

2008


Earth has zero potential then what would be the neutral potential ?

1388


when ID fan will immediately stop through VFD what exactly cause and problem the ID fan

1414


300m long and 30kw inductive loade 3phase supply how many size cable required

1402


How wire size can define in electrical wiring? What is the ratio?

2262


what is the safety of voltage power transformer(2250KVA0

1954


What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439

990


How to decide no. of Step and Kvar for APFC Panel 40 kvar MD: 33.12 KVA Avg pf : 0.8540

1074


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3257


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

2273