Can CT Secondary left open circuited and why(reason)?
Answer Posted / bharat sharma
Let us assume we have 600 V and 200 A on primary side of the
CT. Ct ratio is 200:1 In that case Secondary voltage would
be (600V x 200A)/1A = 120000 V. Would you like to leave
120000 V open circuit irrespective of current capacity of
secondary circuit?
Is This Answer Correct ? | 8 Yes | 10 No |
Post New Answer View All Answers
how to select the isolation tranformer for siemens 802dsl cnotroller
what is RFID? thire application;
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
what is circuit breaker in transfomer and where it used
Explain the following and how these are working with PLC Unit 1 I/O Module Card 2 Adaptor Card 3 Ribbon Adaptor 4 I/O bus 5 I/O Devices
whats the existence of reactive power and when it arises?
What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer
I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF
why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)
how to remover corona effect and hysteresis losses from contactor
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
what happen ehen synchronisation is done at below rated speed
please describe the Transformer setting, Motor setting, I/C setting, Tie setting