Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If i want to build 230kv substation what are the equipments
to be installed?

Answer Posted / viswanathan karthikeyan

Basic Concept :
Incomer
Outgoings
Main Incomer -Cable or OHL LINE -PLEASE CONSIDER
STEPDOWN AUTO TRANSFORMER-220/132kV
NEXT AGAIN STEPDOEN TRANSFORMER-132/33Kv
stepdown Transformer-33/0.415kV

MAIN INCOMER NEED CIRCUIT BREAKER
220KV GIS
132KV GIS
33KV GIS

IF OHL LINE MEANS
gantry
WAVE TRAP
SURGE ARRESTER
COUPLING CAPACITOR
AAAC CONDUCTORS,TOWERS ETC(d0,d2,d6,d9,dt)

CABLE MEANS
220KV CABLE

CONTROL AND REALY PANELS
220,132,33 FOR RELAY AND PROTECTION PANEL

LV,HV,EHV CABLES
EARTHING MATERIALS
EARTHING AUXILLARY TRANSFORMER]
NEUTRAL EARTHING TRANSFORMER

TELECOMMUNICATION PANEL
SCS SYSTEM
BATTERY AND BATTERY CHARGES
EOT CRANE
PUMPROOM
LIGHTING AND LIGHTNING PROTECTION
EARTHING MATERIALS ETC

SO MANY ITEMS REQUIRED

I AM DOING THIS TYPE OF PROJECT
IF ANY DOUBT ,PLEASE SEND MAIL TO ME-vkn.1980@gmail.com

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If a high resistance fault occurs,then what are the changes will happen in the system?

1398


I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok

1613


EXPLAIN THE TRANSFORMER MAINTENANCE?

2209


if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?

1371


what is the meaning of WYE and DELTA in Electric meter?

3770


Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?

2080


what is fault level of power system ?

6214


how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?

2152


how to avoid Saturation in C.T?

2056


what are the accessories need to be added while doing estimation for the following: 1.MCCB 2.MCB 3.ACB

2051


What are the material used for resistor?

1060


What are the basic & Majour problems in UPS ?

2073


Why DG set is not installed in Terrace ??

932


State the factors, for the choice of electrical system for an aero turbine.

1118


How to decide whether A / B / C / D curve type MCB should be used?

2234