Why only negative 24 vdc supply give in vibration measuring
system.
Answer Posted / nandan
The principle is that analyzer supplies a negative voltage
to transducer,who converts it into a frequency & sends it
across the probe.Now as the probe comes into the area of
rotor it creates a magnetic field & with it eddy current is
produced on the rotor side.Which changes the amplitude of
the frequency.It induces the voltage & remaining frequency
comes to the transducer through the return way.Transducer
converts it into the voltage .
Now coming back to the question The gap voltage has a
negative relation with the voltage induced i.e. as the gap
increases the induced voltage decreases.So to make it to
into a linear relation ship, negative voltage is supplied.
i.e
Gap Gap voltage
0 mm 0 vtg
1 mm -9 voltage
2 mm 18 voltage
& when the probe is in air it will have no induced voltage
so all -24 voltage without induced voltage will return back.
| Is This Answer Correct ? | 16 Yes | 7 No |
Post New Answer View All Answers
How digital input and digital output 's are working in dcs
Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks
what is isloted barrier how it works and what are the main purpose.how it make safe area.
I have energy meter for educational project having 0.5s class but my friend need 0.2s class meter , which one is good for that purpose and what is the actual difference of that two classes , need very easy example also.??
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
what is the procedure of belt scale calibration?
wich is coming the first HAZOP OR SIL
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
How d.p. Transmitter can be applied to open tank?
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
How to fix back the valve actuator stem
What is motion balance principle?
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?
why is an oxygen sensor used in a boiler stack
How to calibrate Magnetic flow Transmitter in Field