Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Pls say , how we calculate lux / sq.ft, which formula used
for calculation

Answer Posted / aarya

To Calculate the no. of fittings in a room,
the formula is
N=No. of Light fittings required= A x E/(Lxuxd.f)
.'. E= N x (Lxuxd.f)/A
where L=> Lumen o/p
A=> Area (m^2)
E=> Illumination or Lux levels (in lux)
u=> coefficient of utilization
d.f=> Depreciation Factor
For Detail study refer Philips,G.E(lighting)& Artlite
Catalogues.

Is This Answer Correct ?    18 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..

2007


What is the source of dependent source ?

1907


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

2097


what will be the maximum winding temperature of 6.6kv HT motor 450kw, Full load current 49A. 50Hz Frequency.

3250


i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com

2036


How to connect the chemical earthing and complete process tell me plz

1875


I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?

3308


working principle of oil startar

1904


what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?

1981


FEINGING DECREASES THE FLUX DENSITY IN THE AIR GAP. HOW?

2203


what is the usage of microcontroller in the panel board?

2102


Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.

9613


Is it a better option to procure screw type air compressor rather than reciprocating air compressor?If so, what is the reason?How should we select an air compressor(100 CFM)? Please mention the important parameters of air compressor.

1982


In a tap changing transformer where is the tap connected, is it connected in the primary side or secondary side?

1150


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

2118