Pls say , how we calculate lux / sq.ft, which formula used
for calculation

Answer Posted / aarya

To Calculate the no. of fittings in a room,
the formula is
N=No. of Light fittings required= A x E/(Lxuxd.f)
.'. E= N x (Lxuxd.f)/A
where L=> Lumen o/p
A=> Area (m^2)
E=> Illumination or Lux levels (in lux)
u=> coefficient of utilization
d.f=> Depreciation Factor
For Detail study refer Philips,G.E(lighting)& Artlite
Catalogues.

Is This Answer Correct ?    18 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the types of feedback oscillators?

823


what is meant by 3rd hormonics ?

1490


What is the difference between grid and off- grid system??

1489


How is the percentage impedence of a transformer fixed at design stage???

1506


why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points

1617






The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.

1492


Give two basic speed control scheme of dc shunt motor?

632


how electrical earthing maintenance done in industry?

1039


what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?

1924


what is mean by Digital Logic Meter (DLM)

1864


Write a note on Treatment for electric shock.

1420


WHAT IS ELECTRICAL MAINTAINTENCE ?

1565


How to use computer cpu ups use for home inverter circuit board

1295


What are the disadvantages of hydropower?

663


Can double compression glands be used with regular cables?

1654