What should be the earthing resistance of an industrial
substation and also What should be the house hold earthing
resistance?
Answer Posted / yohanraja
For residential it should be below 1 ohms. For EHV stations
and constructions it should be maintained below 0.5ohms.
And for LC systems it should be maintained below 5 ohms.
Is This Answer Correct ? | 18 Yes | 12 No |
Post New Answer View All Answers
What is genrally the % Impedance of a Dg set? How can we calculate Earthing conductor size for a DG set?
what is subtransient , transient and steady stateac components
exolain the star delta connection
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?
what is the common earth
What is distance between electrical panel to land ?
5.WHICH TYPE WELDING PROCESSES USES NON CONSUMABLE ELECTRODE.........
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
please forward me the type of questions which would rise while me attending to 33KV Electrical License to my mail ID:vadrevu_raghava@yahoo.co.in
delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?
How to calculate mf when meter equipment and meter are connected
Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel
Electrical Engineering