Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how we are measuring the winding temperature of the
transformer?

Answer Posted / vishal shah

hello Mr. V Ram
Windin Temp. Can be measured with the help of Inbuilt-
Thermal Image type WTI (Winding Temp. Indicator)

The Winding is the component with highest temperature
within the transformer and, above all, the one subject to
the fastest temperature increase as the load increases.
Thus to have total control of the temperature parameter
within transformer, the temperature of the winding as well
as top oil, must be measured. An indirect system is used to
measure winding temperature, since it is dangerous to place
a sensor close to winding due to the high voltage. The
indirect measurement is done by means of a Built-in Thermal
Image.

Winding Temperature Indicator is equipped with a specially
designed Heater which is placed around the operating
bellows through which passes a current proportional to the
current passing through the transformer winding subject to
a given load. Winding Temperature is measured by connecting
the CT Secondary of the Transformer through a shunt
resistor inside the Winding Temperature Indicator to the
Heater Coil around the operating Bellows. It is possible to
adjust gradient by means of Shunt Resistor
In this way the value of the winding temperature indicated
by the instrument will be equal to the one planned by the
transformer manufacturer for a given transformer load.

logon to www.scientificcontrols.com for further details
regarding OTI & WTI

Is This Answer Correct ?    33 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1811


a simple c++ program to calculate simple interst with its data members as private

1797


how to test YNyn0 vector group in transformer?

3800


CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)

1781


how much UPS neutral erath leakage current.

3646


hi can anyone pls tell me the eee interview core questions asked in l&t

1982


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

1930


What types domain of laplace transforms? What behavior can laplace transform predict how the system work?

1082


How to know the Max. current caring capacity of the cable by its size ?

1589


How to test REF relay testing for LV panel as per Kahramaa standard?

4877


I am experienced with house and industrial wiring but I don't have any licence how can I apply an licence and which type of licence i can get i didn't complete deee just only experience

1576


how is control wiring coding is done in a CRP panel ?

1958


What aturn on methods of scr?

1109


The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current

2034


any application of back emf

2066