why we used to transmitt the power at higher voltage why
not at lower voltage

Answer Posted / shahin

the main reson for high voltage transmission for reducing
line loss and improving the efficiency. Another reason for
high voltage transmission is Long distance transmission.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1533


Alternator rotor earth fault relay circuit

1556


The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3208


Explain dc generator with its types?

642


What Should be the value of Vector Surge angle at Tripping and how to calculate it?

1595






I have iti elec, 1st aid, and 5 yrs experience in 7.5 mw power plant. Am i eligeble for 11kv license in telangana state..when, how to apply for that.?

1852


dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour

1516


concept of busbar and load dispatching..?

1931


What are the effects of adding a zero to a system?

682


what is efficient motors and how it is different from normal induction motors

1433


Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially

1572


Why 1/3 is used in symmetrical components?

1390


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1671


Explain the purpose of inductor in an electric circuit?

642


What is the distance between each insulator in 33kv transformer and how can it calculate

1766