If the supply voltage is same (say 440V) whether a system
designed for 60 Hz frequency will work with 50 Hz frequency
or not , if so pl. give clarification.
Answer Posted / shahin
Dear all I've seen that all r telling dc motor, ac motor,
converter etc. ABB has asked for a system not for motor/
inverter. As the equaiton of joysbag reduction of frequency
of 10% will cause increment of 16.67% of flux. Though the
system is designed about 60Hz. Then the system component
may be malfunctioning. All of equipments of the system must
be changed as frequency has changed.....
| Is This Answer Correct ? | 10 Yes | 1 No |
Post New Answer View All Answers
High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?
What are the components of feedback control system?
Please brief what is sinewave
we have a 2.5hp Starite electric motor water pump,the elec motor burned out,we need to replace starting capacitor(old capacitor specs erased),what microfarad rating capacitor do we need? 110-125V
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.
Define cut-off rate?
what you have to see after one week or month from the day of installation of transformer ?
what are the protecyion of transformer & generators
How phase displacement change in the over current relay coils.
Is RTCC panel needs any control supply.
Advantages of using generator circuit breaker (GCB) scheme in a power station ?
Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.
True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...