Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY FLEXI LINKS ARE USED INBETWEEN GENERATOR TERMINAL
OUTPUT & BUS DUCT CONDUCTOR.

Answer Posted / surender singh

In output of Generator terminal and Bus duct ,we use flexi
links ie no hard connection because to avoid the transfer of
vibration of generator to bus duct.

Is This Answer Correct ?    12 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1753


What is the normal phase difference between the voltage and the no-load current in a transformer?

1263


What is the name of the winding to which supply is given?

1179


If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?

2231


Why we use duplex coil and hook switch in telephone system?

5045


what is the constructional difference between a power transformer and potentian transformer?

1764


hi i have applied for lic of india south cenrtal zonal ,hyd. i didnt get hall ticket till now.let me know how can i get form internet

2007


wow to calculate the transformer rating(KVA)

2275


What is depreciation factor?

2279


63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?

2750


what precautions to be taken while desigining a LT,HT panel. Eg-LT panel PCC panel with ACB installed. HT panel VCB panel with VCB installed. & what is main diffrence betwn IP54 & IP55 construction of panel.

3053


How to back charge the Gas turbine generator

2160


does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain

1923


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2303


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3292