Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE DIFFRENCE BETWEEN EARTHED AND UNEARTHED CABLE
(XLPE)?

Answer Posted / ajay patel

Basically, Power Systems are defined as Earthed System,
Resistive Earthed or Un-Earthed System.

Hence, Cables are designed for Earthed & Unearthed Power
System. For Example, 11 kV (E) cable is used for 11 kV
Earthed System & 11 kv (UE) cables are uded for 11 kV not
effectively Earthed System. Insulation Thickness is more of
11 kV (UE) cables compare to 11kV (E) cables.

Is This Answer Correct ?    40 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?

1981


how can i find cable size from current rating?

1808


(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?

2094


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2798


How can we calculate the KVA rating of a Distribution transformer from its core details?

2125


Why a tesa lamp is glow between two phase?

2047


what is meaning of bus riser

2660


What is bode plot?

1302


send me any model test paper of clerical post of state bank of india.......

1895


Types of test in Switchgears, MCC, NGR and DB's how it should be procced. Can anyone give me the details here or email me to pasuvaraj.k@gmail.com

2165


how can we determine size of a cable by knowing the kw or current rating of a load?how can we calculate the resistance box of a slip ring motor?

1825


what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights

1974


Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response

2970


How does a battary stores charge in it? please explain in simple manner and in detail.thanks

2034


1.WHAT IS A SMART CAPABLE DB ( DISTRIBUTION BOX) ? 2. HOW TO DECIDE THE TYPE OF DB TO BE USED ( RECESSED/ PLUG TYPE/ SMART ETC ETC? 3. WHAT IS MILLENEUM BUS BAR USED IN DB? 4.DIFFERENTIATE MCCB AND MCB.

1892