Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can we find out earth leakage,(shock)in side the house?..
(with out ELCB)

Answer Posted / barjinder

we can find the leakage inside the house
1.by pouring water on the doubted surface .one would see the
bubbles arising frm the leadkage point

Is This Answer Correct ?    3 Yes 19 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can you explain about Restricited earth fault protection scheme

1800


what is reactive power?, why its measured in VA ? is it transient behavior of system?

2243


What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?

1926


Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632

2696


WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT

3106


What is the difference between vector surge relay (78) and Pole slip relay (98G)

1148


What is the general system requirement of alternator?

1799


How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva

1597


How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?

1750


What happen when change order of CT in GIS feeder?

1593


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1759


If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..

2442


what is the difference between c power and U power acb breaker

6322


If VFD is On but no starting commond on it. so how many outpout voltages of VFD

1101


What are the material used for resistor?

1053