Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In a Dyn11 transformer, how are the 3 windings of the delta
connected? Assume that R1-R2, Y1-Y2, B1-B2 are the 3
windings on the HV side.

Answer Posted / s.arunkumar

the delta connection will be at 11'o clock position vector
group

Is This Answer Correct ?    6 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS MEANT BY SHEATH VOLTAGE IN 132Kv cable?

2340


What are the various kind of cables used for transmission?

1145


i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.

1988


What do you understand by oldham's coupling ?

1127


why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?

3724


What is a copper loss or i2r loss pc?

1198


what is the method of earthing of a transformer using electrodes?

2335


what are the analog quality input for protection function?what are minimum reqiments?

1902


write a c++ code that receives an integer number and display the sum of the number and its revers integer?

2083


please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com

2241


why any centrifugal blower draw more current in starting. consider id fan and fd fan?

1894


What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?

2576


what does a k rating in a transformer means?

2557


What is the de rating factor of cable? What is the importance of the de rating factor in cable selection?

2159


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1730