Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the working difference b/w softstarter and
Variable frequency drive ?

Answer Posted / pardeep.kumar/hoshair pur/

Dear All,
VFD variable frequency drive means it will operate as per
our selected accelration de accelationa nd torque boost.

And Soft starter is device which will limit our starting
torque also.
Its majour application is in textile,A motor of 50 hp
connected to 150 spindles in which thread is unwinding from
samll cone to big cone,if it will start by a normal vfd or
direct start then due to large torque in starting as per
induction motor charecterstics,all thread will get broken.
But due to Softstarter it will limit the starting torque.
Soft starter limits the torque by limiting its current and
voltage. thats all.

Is This Answer Correct ?    5 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?

3095


how to calculate the no load current in transformer?

2569


sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.

1956


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

2038


wish of these transformer uses oil?

1672


What is meant by time harmonics and space harmonics?

2852


Phase control and integral control are used for?

2392


which protection function should measure RMS value of current&DFT value of current?

2136


What is sink and source?

1252


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1730


In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?

2012


Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.

1967


1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?

2741


how can calculation ate Amps for cabel. Ex-for 1sqmm wire hou many amps we can draw

2516


HOW TO CALCULATE S/C,O/C,E/F OF ACB.

2628