Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

On what factors the generating voltage depends ?
Generating voltage are (3.3kV, 6.6KV , 11KV, 13.8kV) Why so ?

Answer Posted / atreya

generating voltage= (P*B*N*Z)/ (60*A)
where,
P= no. of poles of the m/c
B= flux or excitation given
N= speed of rotation
Z= no. of conductors
A= no. of parallel paths for flow of current
(for lap wound m/c s: no. of paths= no. of poles)
(for wave wound m/c s: no. of paths= 2)

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why different Pressure switch used in marine boiler water circulation system

1713


what is the purpose of shading ring or shading coil in electrical equipments.

4410


what is destructive and non-destructive testing of welding

1626


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1832


Best way to measure the Soil resistance of rocky soil, three probe method and four probe method

1881


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1689


How to set a Zone 1 distance relay for distribution feeder?

1959


can we synchronize star system generators with delta system generators?

1999


Do Phase angle measurement have any application in freq/harmonics measurement? If so how?

1889


How we can recongnise the phase displacement of transformer connection between primary & scondary...plzzz explain it with example.........

2454


What is depreciation factor?

2220


electrical ques

2084


What are the weight of 800KV DA,DB and DC type tower ?

3078


Why generation voltage in thermal power plant is between 11kv to 33kv?

987


What should be the protection scheme for a 15kw, 3-phase motor working in a lathe machine.

2017