Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

The potential difference between a phase and neutral is
230v , but the potential difference between two phases is
400v. why?

Answer Posted / mohan

phase to phase displacement is 120degree and magnitude
same.but nutral voltage is zero

Is This Answer Correct ?    22 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what about GD square and its important for motor design?

3763


What is deference between MCB & MCCB & ISOLATOR

2048


WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....

1909


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

2044


Why HT 11 KV Slipring Motors are connected in star ?

2165


what is the safety points of vaccum circuit breaker.

2025


When is lag lead compensator is required?

1071


Why we are use dol starter up to 10 hp

1321


Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more

1990


Please explain me about Relay curves and their sources to read ?

1759


WHY THREE PHESE SYSTEM VOLTAGE APPLIED IN 440 VOLT

2278


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2017


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1831


How you give clearance to a spare feeder.

1638


When color of silica gel will gets change from blue to pink from Top to bottom?

1548