Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?



Answer Posted / rajesh

1.HART is Communication Protocal.it is used to Communicate
the Field Instruments for measuring and Calibrating purpose
2.K Type : 0-1370 degrees
J Type: 0-700 degress
B Type: 200 -1800 deggress
R type: 200 - 2450 degrees
Output of Thermocouple is DC Potential (milli volts)
3.Platimum RTD :PT-100 Range:-270 to 600 degress
Output of RTD is Resistance
4.Temparaure tranmitters
it will receive the sinal from sensor (thermocouple /
RTD) and this signal will convets to 4-20mA or 0-20mA
5.Analog Signal is contioues measuring signal ie it's
measuring Range is 0 to 100%
Digital signal is a Binary form ie. Its state is Either
High (1) or Low(0)
6.in 4 wire Tranmitter Have Seperate exitation Supply is
for its Operation and Output taken for seperately.if the
Tranmitter Elecronic Cercuit is drawing More than 4 ma of
current then it will apply the 4 wire scheme.
in 2 wire Tranmitter working supply and its output is
taken in same cable.ie its working supply is lessthan 4 ma.

Is This Answer Correct ?    63 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Galvanizing.

1946


what is intrinscily safe system and where we use?

2507


What is stripper & spilitter ? Diffrence in this.?

2466


what is the responsibility of an instrument commissioning supervisor

3150


NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal

2183


Why mixer nd grinder Is example of constant torque load not variable torque load ???

1940


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2677


I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.

1930


what is gas metering system? gas chromatograph? and gas compressors?

2445


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

2071


How to Calibrate Ultrasonic Level Transmitter in field

1348


How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks

2096


how the arrangement of equipments done in control room

2001


What is the procedure of calibration of Load cell?

1914


what is function of switch, and how is it work, explain with difination

2358