Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the working difference b/w softstarter and
Variable frequency drive ?

Answer Posted / senindra123

soft starters is using for smooth starting only which will
be by paseed while running.

variable frequency drives are using for smooth atarting and
running. while running we can control the speed of the
motor also.

Is This Answer Correct ?    18 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the factors to be considered while design the breaker either HT or LT??

1823


how to select electronic timer(Star-Delta) setting for diff. rating motors

1905


How to decide and select the different earthing wire size for the different types of earthing

2218


EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)

8191


what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field

1949


what type of earthing do for dry fissure rock?

2395


700KW 6.6KV slip ring induction motor to use VFD to control the speed

3153


Please explain, how to test vector group of tranformer(Delta y1) . Thank

1657


What do you understand by external characteristics of a d.c. Generator?

1059


When color of silica gel will gets change from blue to pink from Top to bottom?

1547


I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN

2048


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2058


what is saturation kit?which use above 15 kw motors panel side.

4138


How can ou verify the size of conductor 50Sq.mm ACSR

1884


what is the meaning of WYE and DELTA in Electric meter?

3762