Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

when a three phase motor in running condition consumes 2A
in each phase,and if one of the phase gets fails what will
be the consumption in other two phases

Answer Posted / pratheesh

If one of the phase fails when a 3phase induction motor
is running, motor will continue running with a 25
percentage of more current in other 2phases.
If the thermal overload protection is not working
perfectly, the motor winding may burn.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is RNG in the DG synchronizing by PLC?

2176


What do you mean by a phase angel of instrument transformer?

1155


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2505


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

2228


what is auto re-closer?

2723


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

1464


In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?

1753


can i connect wavetrap in 2 different phase in EHV line?

1920


what is ps impedance test

2183


Whats the difference btwn a latch, port,data bus buffer? Do they all not hold data in d flip flops??

2456


What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?

1723


How out of step protection relay works?

2533


please send me RRB electrical engineer previous year questions for Sr. Section Engineer

2001


I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.

1773


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1697