How to calculate the average power factor in 3 phase
unbalanced system
Answer Posted / razi zainal abidin
Dear all,
This is not an answer, actually question.
In one factory, we are dificult to measure resistance,R and
impedance, Z.
What we have is only voltage supply (3phase, 420volt), and
total current flow during maximum usage using clampmeter
(including machinery, lamp, computers, etc...)
We also have info of main transformer step down because it
is in the factory area. Normally they stated value of KVA.
And some factory already install the 'capasitor bank
regulator'
So, how we can calculate the CORRECT VALUE of capasitor
need to install?
I mean, which one is the correct KW, which one is the
correct KVA, and how to calculate existing power factor IF
the factory already have 'capasitor bank regulator'....can
we switsh of the regulator?
| Is This Answer Correct ? | 5 Yes | 4 No |
Post New Answer View All Answers
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.
how to select electronic timer(Star-Delta) setting for diff. rating motors
what happen when increase or decrease size of lamp,light.glass.
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
What are the three types of compensators?
explain different losses in a transformer.
Initially, when the input is not equal to the output — what type of response is this?
what type of questions are asked and howmwny questions belong this catagory?
what kvrah y we need to take the readind of that
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
How to minimize the eddy current losses?
What does bode plots shows?
what is the Transformer Impedence?How can calculate?
How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance