Transformer's core is made up of which material and why so?

Answer Posted / monalisa rout

softiron because it reduces eddy current loss

Is This Answer Correct ?    5 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

are there rmu for 3 transformer?

1428


What is different between Circuit breaker and Isolater?

1233


what type of questions are asked and howmwny questions belong this catagory?

1720


What id difference between power and energy?

664


what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks

1747






How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

1483


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1235


How is the connection of the tap changer on the HV side been made?

1520


why are the maintaine power factor and how can this control and this is how work.

1490


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1269


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1245


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

1884


How it can worked plc based electrical system And which type of software using.

1678


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

1610


what are the applications of transistors with low dc gain, high dc gain and medium dc gain( beta)?

1308