what is full form of SMART

Answer Posted / sumit kumar

Self-Monitoring, Analysis, and Reporting Technology

Is This Answer Correct ?    153 Yes 59 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1034


What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

635


Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com

492


How does your previous experience relate to the job you are applying for ?

1562


Draw a simple circuit for a well head control panel used to protect the well against fire, leak, blockage, ESD, & controls the operation of one downhole & one surface safety valve. Explain the operation and controls

1165






need instrumentation job completed 1 year trainee ship in mnc pesticide company. now in search of job

1484


Isometric drawings are generated during _________________ phase of a project

1619


Why do we have earthing cable in branch cable and shield in the same cable?

2151


How many are the types of instrument cables in terms of No. of pair.

1711


What is hp & mp seperator .& what is its working principle ?

1828


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

1960


what is SIL 1 2 3

1550


diff between neutral ,ground,phase , earthing and shielding?

1874


what is the reset offset and control system in instrumentation

3123


How signals can be taken through modbus?

690