HOW many type of Circut Breaker in the world used in 400 kv
substation?
Answer Posted / raju pal
befor we are using ABCB type out door circuit breker.
now we are using sf6 fild out door circuit breker, like
abb , areva, simens are manufactur.
| Is This Answer Correct ? | 23 Yes | 4 No |
Post New Answer View All Answers
How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15
What mean by MLTP
Transformer cores are laminated in order to A simplify its construction B minimize eddy current loss C reduce cost D reduce hysterisis loss
why we use circuit breakers for switching instead of normal switching device?
what is the preventive maintence for ht panels and busbars and vcb abd acb's.
Lt motor sfu flashing reasons?
Explain with example of functional requirements of protection relay in terms reliability, selectivity, sensitivity
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you
please I wont know how to calculate the vector group for power transformer ZNyn11 best regard.
how meger function
neutral earth resistance testing is it possible for transformer while in load condition
what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?
ACB & VCB how do work and saftes and how can maintenance in this and parts name show with picture
What id difference between power and energy?