Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

On what factors the generating voltage depends ?
Generating voltage are (3.3kV, 6.6KV , 11KV, 13.8kV) Why so ?

Answer Posted / sanjib pramanick

Generating voltage depend mainly on field
excitation.Generating voltage are 3.3kv, 6.6kv, 11kv like
that because of from factor.We are using sinusoidal voltage
in our system and its from factor is 1.11.

Is This Answer Correct ?    21 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Types of test in Switchgears, MCC, NGR and DB's how it should be procced. Can anyone give me the details here or email me to pasuvaraj.k@gmail.com

2165


WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI

2124


What Is HO factor in power selection

2121


Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.

2178


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1427


How to connect the chemical earthing and complete process tell me plz

1915


Give some example of fault limiting devices?

1426


In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)

1831


what is ground fault in ACB?

2155


IF 8255 CONTROL WORD IS 94H,Tell the chip port work mode ?

2614


what is p.s impedance measurement test in earthing transformer?

2470


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2912


What is the basis for framing the rules of block diagram reduction technique?

1582


how to increase or decrease speed in DC shunt motor by DC convertor

2323


I want the details about BHEL company examination.Can anyone able to help me please.

2095