Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which is more dangerous A.c or D.C?

Answer Posted / srihari

dangerous is dependent upon the voltage and current
levels.in case of d.c . low voltages in between 40v to 150
v is danger than high voltage,but in case of a.c
highvoltages are very dangerous

Is This Answer Correct ?    5 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to see the inductance in a transmission lines

2144


What type of core material is used for metering C.T and protection C.T???

2074


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2130


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.

1988


Why corona leads to production of Ozone and glow of the color VOILET?

1978


Write the current equation in series RLC circuits.

1143


Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?

1803


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1948


3Cx240 & 3Cx300 sqmm Al. cable from lv side. What is the calculation for this cable??

1410


How can we checked Killo Watts of Motor & Alternator?

2154


Difference between drift current and diffusion current?

1879


How earthing of switchgear system to be done.

1933


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1649


why is a power transformer used only occasionally?it is used to step up at generating stations?and that needs to be done all day long !!!!!!!

1871


how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.

2390