Answer Posted / abdul nazir
Starter is used to help the choke to produce "self
induction". I will explain little briefly.
initially we need 1000v to start the tubelight,so one chohe
was connected series between the tubelight & other end of
the tube light was connected with starter.
In this starter inside it contains one bimetal strip(open
position)& parallel connected with one capacitor,inside the
starter full of argon gases.
initially the supply will go through the choke,tube light &
starter.
Already starter inside bimetal strip was in open condition
so supply will not pass it, inside argon gases are present,
so arc will produce between the bimetal strip & it will
close the ciruit(due to heat), so supply will pass throug
it, after then bitmetal stip getting cool and it will open
the contacts.
Immediately the choke gives 1000v due to self induction, so
inside the tube light ionsation was happens & start the light.
why capacitor is used inside the starter? To avoid the Radio
interference.(In our home television or radio is working at
that time if we switch on the tube light little bit noise
will come from the tv or radio, if the capacitor was not
there the noise will be very more this is called radio
interference.)
| Is This Answer Correct ? | 107 Yes | 11 No |
Post New Answer View All Answers
which type of cabel
how to test and calculat the head and discharge in borewell compressor
what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering
can we use ZNyn11 transformer instead of Dyn11 transformer in distribution for effectively eliminating harmonics from the industrial loads.
what r PID controllers?why they r used?what is there purpose?plz Explain in detail
why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?
how much flux density of CRNO core
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is meant by rotating magnetic filed
what is Fan Control Cubicle
What are the different types of hydro schemes?
why we change the direction of winding in rotor ?how we make the north and south pole?
What is vacuum circuit breaker.define with cause and where be use it device?
Please give me a erda placement paper
How much minimum insulation required between 11kv/3.3kv transformer windings?