Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS DGA TEST FOR THE TRANSFORMERS.

Answer Posted / jadhav padmakar

DGA Means Dissolved Gas Analysis. While in service
Transformer undergoes various termal,chemical,electrical
stresses due to that some gases generated these gases known
as Fault gases which r quantitified in extremely low level
in Parts Per Million (PPM), the test which is conducted to
analyse these fault gases known as DGA Test.

Is This Answer Correct ?    65 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Pls explan the OLR setting in VCB at HT yard

2679


Formulae for calculating the transmission line losses for different voltage levels

2168


What is the Current equation in series RLC circuits.

1040


what is conductor constant of raccun conductor

2222


Draw a SLD of DG distribution up to main LT panel?

9472


What are the difference between normal application Transformer and Solar application Transformer?

1648


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1791


th how could we differentiate between armoured copper and armoured aluminium cable what is the basic application? why we prefer the armoured copper as compared to armoured aluminium.

1956


What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva

2203


How two nos. 130 kw D.C motor get synchronise using D.C drive.

2118


whatis the commertial spec. of distribution boards ?

2065


Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?

2324


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1770


describe the Operation of induction generators from bus bars

2309


Can i use the B-curve MCB instead of C-curve MCB

2018