Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happens to the speed of a DC series motor when series
field winding is removed?

Answer Posted / raymond johnson

In a series wound motor, the stator is connected in series with the rotor so, if the series winding (stator) is opened, current ceases to flow thru the motor and it will come to a stop.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is MEN and RCD related to each other ?? IF yes then how??

1929


How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester.

2388


what is diff btw electric,magnetic & eletromagnetic field

2188


working principle a.v.r. ?

2494


why there using acb enclosure in big buildings

2159


How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?

2237


neutral earth resistance testing is it possible for transformer while in load condition

2015


what is the thumb rule for determination resistance of resistor?

2371


What are the significant parts of dc generator?

1211


what is the reason the main breaker is trip during the motor is running? (some time the breaker is not trip)

1830


HOW MUCH CURRENT DOES SYNCHRONOUS MOTOR TAKES AT SYNCHRONOUS SPEED IN NO LOAD CONDITION ?

1908


from which subjects most of the technical que will b asked for hpcl(electrical).pls help me

2062


how oil in the MOCB was reduced compared with OCB? what are the features of the MOCB?

2833


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2131


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

2054