Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why capacitor bank does not require in DG Set?

Answer Posted / abdul nazir

If Dg set is running parallel with grid we can adjust the
power factor through excitation, but if it is running in
ideal mode we cant adjust the power factor through
excitation, so we need capacitor bank at that time.

Is This Answer Correct ?    5 Yes 23 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the actual meaning of thermal power efficiency ?

2060


Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?

2121


which metal is use in shunt

6395


if i get a drop in my 1st year and the i clear my 2nd year and 3rd year all clear and i dont have any back logs so can i be able to sit in campus selection??

1810


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

2026


2. A current i=(10+10 sin t)amperes is passed through MI type ammeter. its reading will be.........

2273


Why the efficiency of a three-phase induction is the motor is less than that of a three-phase transformer?

1085


how much allowable resistance that can be difference in motor all coils?

2273


In Generator How suction compression power and exhaust works ?

1894


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2081


explain the mode of metal iranafer in Co,welding

1522


How can two 3 phase transformers of same KVA and Voltage be connected in parallel?

1807


is it possible to have dc motors on single chip

1775


state working of halogen lamp?

1771


i have a 1500kVA transformer what is the kWH meter i need to use?

1712