Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Relay and Contactor

Answer Posted / vikrant patel

First Clear Relay Means
1. Protective relay
2. Control Relay.

If talking about Protective relay (Example: over current
Relay, Electronic motor protection relay..etc)
so protective relay is for Protection of circuit
and functionally different from contactor.
they have only potential free contact at output which can
be used in control circuit.

if talking about control relay
1. Power relay (which have Change over contact with high
current capacity)
2. Solid state relay
3. Simple control relay. (Which have Change over contact
with low current capacity call SPDT)

This all relay has functionally similarity with contactor
that they are electromagnetic device (except SSR) but
difference
- relay have changeover contact (NO, NC& Common) while
contactor have power contact NO) & auxiliary contact (NO or
NC).

Main difference is

- Contactor is used to Control power Circuit while relay
are used for control circuit (except Power relay which is
now a days introduce for DC/High voltage application).

Is This Answer Correct ?    117 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is a vector protection in transformer

2025


Why air circuit breaker off due to power failure?

1213


What does the term power factor shows?

1123


Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.

1780


Explain how you intend to work under pressure to meet up with deadline target?

2392


What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?

3955


wish of these transformer uses oil?

1627


which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1932


what is the question paper model for section engineer in RRB

1893


hello! sir i did three year of diploma in electrical (2007- 2010) and now i m a student of electrical engineering. sir can i apply for germany visa for study and part tome work over there?

1844


State ohm’s law?

1109


distribution is maximum done by a)radial b)network c) parallel d)b & c

2015


what is a bus post insulator? explain its application in a substation.

12603


what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?

2264


Difference between low impedance and high impedance Restricted Earth Fault

3120