How to calculate kva? what is the formula.
Answer Posted / sudheer
KW = KVA X p.f
KVA= KW/ P.F
P.F= kw/KVA
KVAR= KVA.Sin theta
| Is This Answer Correct ? | 73 Yes | 14 No |
Post New Answer View All Answers
what is solkor relay and which condition it will act?
hi friend i am going too attend for hpcl in this month please help me by sending written test question papers i am in the stream of E.E.E
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
what is transistors comprised of?
Different STANDARDS (BS, IS, IEC etc) gives different informations on CT specification. How they correspons w r t each other (i.e I mean to say BS provides "knee point voltage" but IS does not, then how can i select CT)
WHAT IS MEANT BY TV TERMINAL IN 500MVA TRANSFORMER?
What is the effect of pd controller on system performance?
what is meant by residual over voltage & residual earth fault ?
why occ characteristics curve in not tracing back when we are bringing back the rhoestat?
1hp= how much rpm
Is it possible to connect a safety device in to parallel?
Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?
how freewheeling diode improves the powerfactor
When we giving the 3 phase supply to ups system how to coming netural?
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?