On what factors the generating voltage depends ?
Generating voltage are (3.3kV, 6.6KV , 11KV, 13.8kV) Why so ?

Answer Posted / sai

due to form factor

Is This Answer Correct ?    17 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.

1733


we use capister for power factor. when we use capaciter in dg circuit  than defect dg. can we use capaciter bank for dg circuit

1446


How will calculate losses in an multi core Aluminium LT cable of different sizes & upto what length we can use a LT Cable ?

1683


DESCRIBE THE CONSTRUCTION ANDOPERATION OF BELT CONVEYORS AND SCR CONVEYORS , DRAW NEAT SKETCHES

1639


what are different types of electrical windings? i know the distributed winding ,concentrated winding etc but i want some detailed information, in what condition we will use distributed,concentrated windings what are the difference between them which is best, how induced emf changes by using different types of windings 20 hours ago - 1 week left to answer

1528






how to calculate regulation constants for over head lines? and what are the regulation constant for raccoon conductor at different voltage level and different P.F?

1476


how oltc works in rectiformers of higher rating (27 mva,200v dc,120kamps) please provide me full information with diaggram.

1728


where can the transformer having vector group Yny0 be used??

3598


i need some project topics along with circuit diagram in the electrical adnd electronics engg and also give ome website regarding projects.my mail id is thenmozhi2k7@gmail.com .please help me.

1455


c++ write a program to use a fuction call "max"which accepts an intger arrey of size5.as an arrument and return the larger and smallest of the arrey to main without changing. the original changing of the original position of the element of the arrey.

1482


Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station

1562


What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?

1473


Can any body tell gulf interview question for experienced electrical engineer ?

1632


how to calculation increase power factor for single phase

1834


in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1425