Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why ELCB can't work if N input of ELCB do not connect to
ground?

Answer Posted / dayal varma

the main function of the ELCB is to trip the circuit when
ever the fault in earth ocuurs so it needs a ground
referance. other wise it will not work

Is This Answer Correct ?    23 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can we choose the rating of submersible motors

2643


If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.

2347


If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.

1972


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1683


How to calculate capacitor bank value to maintain unity power factor with some suitable example?

1152


How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?

2196


What is meant by vector group

2551


Why line VTG = √3 phase VTG in star? How?

1620


what is the effect of un-synchronized power.

2071


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2067


Mention the disadvantages of low power factor? How can it be improved?

1159


how to find number of run cable laying[LT side] for transformer & alternator secondary side? [above condition for getting output power transformer to main panel side] give the example.

2081


what are factors to be consider to design a HT & LT motor?

2327


I NEED RRB SYLABUS FOR JE ELECTRICAL ,PLEASE SEND TO MY E- MAIL ID joo28_eee@yahoo.co.in

2862


aternator every parts and its working

1633